Concealed Ducted AC (Concealed) in Makkah
Makkah — Concealed Ducted AC (Design, Supply, Installation, Commissioning & Comprehensive Maintenance)
In-Depth Technical Overview
Concealed Ducted AC is a DX system with an indoor cooling coil and blower hidden above the false ceiling, feeding an insulated galvanized duct network sized for calculated CFM to supply outlets engineered to minimize noise and drafts. The concealed architecture delivers clean, premium interiors and precise control via a smart thermostat/control panel that manages schedules, setpoints and comfort modes. The system can be complemented with IAQ upgrades (multi-stage filtration, fresh air integration) and is specified with suitable external static pressure to handle duct runs without excessive pressure loss or unwanted sound.
System Components — What Matters in Makkah
- Indoor unit: cooling coil + fan with appropriate external static pressure, multiple speed profiles, and reliable condensate drains with trap/odor seal.
- Outdoor unit: condensing unit with inverter (or on/off as required) compressor and corrosion-protected coils.
- Ductwork: galvanized sheet metal to proper gauge based on run length and target pressure; thermal/acoustic insulation thicknesses selected to prevent condensation and reduce breakout noise.
- Supply/return outlets: grille/diffuser sizing and placement engineered for balanced distribution and the elimination of hot/cold spots.
- Controls: programmable thermostat with local/central integration, temperature/humidity sensors and compressor protection features.
Why Owners in Makkah Prefer Concealed Ducted
- Clean look with no visible indoor units—ideal for upscale apartments, hotels and serviced suites.
- Balanced airflow that reduces operational complaints and keeps comfort stable.
- Less disruption to finished spaces thanks to ceiling-level service access and easier maintenance reach.
Services by “Haboob for Air-Conditioning, Refrigeration & Ventilation” in Makkah
1) Study & Calculations
- Realistic cooling load (envelope, occupancy, lighting, equipment) to determine unit capacity and external static pressure.
- Duct modeling (velocities, friction losses, sound levels), optimized routing to reduce pressure loss, and a room-by-room air balancing plan.
2) Supply & Compliance
- Original concealed units with technical submittals/approvals, fans selected for acoustic performance.
- Sheet-metal gauges and insulation per SMACNA/DW144, flexible hangers and anti-vibration provisions.
3) Execution (Installation)
- Duct fabrication/installation with sealed seams, thermal/acoustic insulation, expansion joints and service openings.
- Refrigerant piping with pressure/leak tests, correctly sloped condensate drainage, anti-vibration bases and electrical protections.
4) Testing & Commissioning (T&C/TAB)
- Deep vacuum and charging, airflow measurements and CFM set-up per room, thermostat calibration, and noise verification.
- Delivery of as-built drawings, equipment schedules, O&M guidance, and a preventive maintenance plan.
5) Maintenance & Support in Makkah
- Scheduled visits for coil/filter cleaning, condensate/pipework checks, controls updates, and local breakdown response.
Competitive Advantages with “Haboob”
- Lower total cost of ownership via optimized fan speeds and part-load operation.
- IAQ upgrades through fresh-air integration and staged filtration when required.
- Flexible expansion/retrofitting when interior layouts change.
FAQ — Makkah
Cost? Final pricing follows site visit and calculations; variables include capacity, duct run lengths, number of outlets and control type.
Noise? We control it through correct velocities/routing, acoustic insulation and suitable grilles.
Timeline? Typically 4–12 days for a standard unit/floorplate, depending on preparatory works.
Warranty? OEM equipment warranty + Hboob installation warranty, with optional preventive maintenance contracts.